2 With a 220 AH battery, We would've got a backup of 8.448 hours, which is much more.

3 220AH battery provides power backup of 2.8 hours on full load of 756 watts and 5.6 hours on half load (378 watts).

4 Backup time of UPS (in hours) = [ Battery rating (in Ah) × Battery rating (in V) × Number of Batteries × Battery Efficiency ] / Load in Watts (W).

How to Calculate UPS/Inverter Battery Backup Time?

In today's world, where power outages are becoming more frequent and unpredictable, having an Uninterruptible Power Supply (UPS) or Inverter at home or office is essential. But how do you calculate the battery backup time of your UPS or Inverter? This question has been a hot topic lately, with many people searching for answers online. In this blog, we will guide you through the steps to calculate your UPS/Inverter battery backup time, using popular methods and techniques. So, let's get started and learn how to ensure uninterrupted power supply during emergencies!

There are different methods to calculate the battery backup time of your UPS/Inverter. Here are two popular methods:

Method 1: Using Battery Capacity and Load

The first method to calculate UPS/Inverter battery backup time is by using the battery capacity and the load. The battery capacity is the amount of energy that the battery can store, while the load is the amount of energy that your appliances or devices consume.

Step 1:Determine the Battery Capacity in Ah

To determine the battery capacity in Ah, check the battery label or manual. For example, if the battery is labeled as 12V 100Ah, the battery capacity is 100Ah.

Step 2:Determine the Load Wattage in W

To determine the load wattage in W, add up the wattage of all the devices connected to the UPS/Inverter. For example, if you have a computer with a power consumption of 150W and a monitor with a power consumption of 50W, the load wattage is 200W.

Step 3: Calculate the Backup Time

To calculate the backup time, use the following formula:

Backup Time (in hours) =Battery Capacity (in Ah) * Battery Voltage (in V) * Battery Efficiency (in %) / Connected Load (in W/h)

For example,

1. If you have a 1500VA UPS with a 12V 100Ah battery, and the total wattage of your load is 800W, the backup time can be calculated as follows:

Backup time = (battery capacity ÷ power requirement of load) × 0.7

Backup time = (12V × 100Ah ÷ 800W) × 0.7

Backup time = 1.05 hours or 63 minutes

Note: The factor of 0.7 is used to account for battery efficiency and other losses.

2. Suppose you have an inverter battery with a capacity of 150 Ah and an input voltage of 12 V, and you want to power three tube lights, three fans, and a Wi-Fi router using this battery. In this scenario, you may be wondering how long your appliances will run on this battery and what will be the battery backup time. To find out, let's calculate the backup time of your inverter battery and determine how long your devices will be powered.

Taking your inputs into consideration, you can calculate your total load, like:

  • 3 tube lights = 40 x 3 = 120 Watts
  • 3 fans = 75 x 3 = 225 Watts
  • 1 Wi-Fi router = 1×20 Watts = 20 Watts

So, the total load in your case is 120 + 225 + 20 = 365 Watts.

Now, let us apply all these values in the above-said battery backup time formula. 

Backup Time (in hours) = 150 x 12 / 365 = 4.9

So, your inverter battery will last around 4.9 hours to keep your needed appliances running. 

 

Method 2: Using Battery Discharge Rate

The second method to calculate UPS/Inverter battery backup time is by using the battery discharge rate. The battery discharge rate is the rate at which the battery discharges during a power outage.

To calculate the backup time using this method, follow these steps:

Step 1:Determine the discharge rate of your battery. This information can usually be found on the battery or in the product manual.

Step 2:Determine the capacity of your battery. This is the same as step 1 in method 1.

Step 3: Calculate the backup time by dividing the capacity of the battery by the discharge rate.

For example, if the discharge rate of your battery is 10A, and the capacity of your battery is 100Ah, the backup time can be calculated as follows:

Backup time = battery capacity ÷ discharge rate

Backup time = 100Ah ÷ 10A

Backup time = 10 hours

 

Calculating UPS/Inverter battery backup time is essential to ensure uninterrupted power supply during emergencies. The two methods discussed in this blog, using battery capacity and load wattage, and using runtime provided by the manufacturer, can help you determine the backup time of your UPS/Inverter accurately. It's important to keep in mind that backup time can vary depending on several factors, such as battery age, temperature, and load type. Therefore, it's recommended to test your UPS/Inverter regularly to ensure optimal performance during power outages.

 

How to Improve Your Inverter Battery’s Backup Time?

If you want to improve your inverter battery's backup time, there are several steps you can take to optimize its performance. Here are a few things you can do:

  1. Choose the Right Battery Capacity: When buying an inverter battery, it's essential to choose the right capacity that meets your needs. The higher the battery capacity, the longer the backup time. Therefore, if you need more backup time, consider buying a battery with a higher capacity.

 

  1. Regular Maintenance: Regular maintenance can significantly improve the performance of your inverter battery. Keep the battery clean and dry, and avoid exposing it to extreme temperatures. Also, check the battery water level and top it up with distilled water if needed.

 

  1. Limit Connected Load: The more devices you connect to your inverter battery, the shorter the backup time. Therefore, it's crucial to limit the number of devices connected to your battery and use only essential appliances during a power outage.

 

  1. Use Energy-Efficient Appliances: Using energy-efficient appliances can help reduce the power consumption of your inverter battery and extend its backup time. Consider replacing your old appliances with new, energy-efficient ones that consume less power.

 

  1. Invest in a Solar Panel: If you live in an area with long power cuts, investing in a solar panel can be a good option. A solar panel can charge your battery during the day, which can significantly increase the backup time of your inverter battery.

By following these tips, you can significantly improve the backup time of your inverter battery and ensure uninterrupted power supply during emergencies.

 

Frequently Asked Questions –

How many hours will a 220Ah battery last?

For example, if you have 1 unit of battery with 12V and the assumed load in Watts is 200 Watts, your calculation will look like: 220 x 12 x 1 x 0.8 / 200 ≈ 10 hours, where 0.8 is the Depth of Discharge. This means that a single battery with a rated capacity of 220Ah will last for about 10 hours with a load of 200 W.

 

What is the difference between 200Ah and 220Ah battery?

What is the difference between 200Ah and 220Ah battery? If one of the numbers is approximate, the difference is approximate. Of course the short answer is 20Ah or 20 Ampere hours. If you have a 200A load, it will be powered for one hour by the 200Ah battery, or 1.1 hours by the 220Ah battery.

 

How many solar panels can charge a 220Ah battery?

Number of Solar Panels Required

In most cases, round-up figures of 1.67 can be obtained. It is wise to round up to the nearest high number, like 2. 
Two solar panels will be sufficient to charge a 220ah inverter battery installed for home appliances.

 

How many watts is A 200Ah battery?

Watt is the unit of power and the amount of power stored in a battery is equal to the multiple of its Voltage and Ampere- hours, hence 12 volts 200Ah battery is equal to 2400 watt (12x200), 24 volts 200 ah battery is equal to 4800 Watt (24 x 200) and a 48 volts 200 Ah battery is equal to 9600 Watt (48 x 200).

 

What is the full form of Ah?

One ampere-hour (or amp-hour or Ah) is a current of one ampere flowing for one hour. The amount of charge transferred in that hour is 3,600 coulombs (ampere-seconds). A milliampere-hour (mAh or milliamp-hour) is a thousandth of an amp-hour. An ampere-second (A-s or amp-second) is an amp supplied for one second.

 

How many watts is a 220 amps battery?

Your battery is capable of storing 12V x 220Ah = 2640 Watt hours.

 

Which is better, 150Ah or 200Ah?

A 200Ah battery has a higher capacity to store electrical energy compared to a 150Ah battery. Specifically, a 200Ah battery has the capacity to store and deliver more charge than a 150Ah battery before requiring a recharge.

 