Can I Use a UPS as an Inverter for Eight Hours?

Can I Use a UPS as an Inverter for Eight Hours
Size:

Can I Use a UPS as an Inverter for Eight Hours

A UPS (Uninterruptible Power Supply) can serve as an inverter for extended backup up to eight hours or more if it is properly sized and paired with a sufficiently large battery bank. Unlike standard inverters, high‑capacity Online UPS systems provide zero transfer time and pure sine‑wave output, protecting sensitive electronics throughout a lengthy outage. By selecting the right UPS model, matching it with batteries of the correct capacity, and managing the load carefully, you can achieve reliable home or office backup for many hours. Lento’s range of DSP‑controlled Online UPS units, combined with tubular, AGM, or lithium‑ion batteries, makes this approach both practical and effective.

 

Introduction

Power outages can last anywhere from a few seconds to several hours. In areas with frequent or prolonged blackouts, a short UPS runtime may not be enough to keep essential devices running. Many people wonder whether a UPS can double as an inverter for extended backup—particularly eight hours or more.

The good news is that modern UPS technology, especially high‑end Online UPS systems, can indeed power your home or office for that duration. However, you must account for three main factors:

  1. The UPS’s power rating
  2. The battery bank’s total capacity
  3. The power draw of connected devices

In this article, we will walk through how to size a UPS system for eight‑hour backup, explain the necessary battery configurations, and highlight Lento’s recommended solutions.

 

UPS vs. Inverter: What’s the Difference?

Although UPS and inverter functions overlap, they are designed for different primary purposes:

  • UPS Systems are built for instantaneous backup with zero transfer time. High‑end Online UPS units continuously convert power, ensuring no interruption when the mains fail. They also regulate voltage and filter out spikes, surges, and harmonics.
  • Inverters convert DC battery power into AC but often have a small switchover delay and limited voltage regulation. They are ideal for longer, lower‑priority backup but may not protect sensitive electronics as thoroughly.

By treating a UPS like an inverter, supplying its inverter stage with power from the battery bank, you can achieve extended runtime with the added benefits of continuous voltage regulation and surge protection.

 

Step 1: Calculate Your Backup Needs

Before selecting equipment, determine which devices must remain powered during an outage and for how long.

  1. List Essential Devices
    • Wi‑Fi router (10–20 W)
    • LED lighting (10–15 W per bulb)
    • Ceiling fan (60–75 W)
    • Laptop or desktop (50–250 W)
    • Refrigerator (150–300 W), if required
  2. Sum Their Power Draw
    For example, a router (15 W), two LED bulbs (2 × 12 W), and a fan (75 W) total 114 W.
  3. Decide Runtime
    Eight hours in this case.

 

Step 2: Choose the Right UPS Capacity

UPS capacity is rated in VA (volt‑amps) or kVA. To convert watts to VA, divide by the power factor (typically 0.8 for UPS systems):

Total Load (W) ÷ 0.8 = Required VA Rating

For a 200 W load:

200 W ÷ 0.8 = 250 VA

To support devices comfortably and allow for headroom, you would choose at least a 500 VA or 1 kVA UPS.

Lento Online UPS Models suitable for home backup include:

  • 1 kVA / 36 VDC
  • 2 kVA / 72 VDC
  • 3 kVA / 96 VDC
  • 5 kVA / 120–180 VDC
  • 7.5 kVA / 180 VDC

 

Step 3: Size Your Battery Bank

The battery bank’s capacity determines how long the UPS can run on battery power. Battery capacity is measured in amp‑hours (Ah) at a given voltage.

Backup Time Formula

Backup Time (hours) = (Battery Voltage × Battery Ah × Number of Strings × Depth of Discharge) ÷ Load (W)

  • Battery Voltage: Total string voltage (e.g., 48 V for four 12 V batteries in series)
  • Battery Ah: Amp‑hour rating of each string
  • Depth of Discharge (DoD): Percentage of battery capacity you plan to use (e.g., 50% to preserve lifespan)
  • Load: Power draw in watts

Example

  • Four 12 V, 150 Ah batteries in series → 48 V string, 150 Ah
  • DoD = 50% → usable capacity = 150 Ah × 48 V × 0.5 = 3,600 Wh
  • Load = 200 W
  • Backup Time = 3,600 Wh ÷ 200 W = 18 hours

In this scenario, a single string of four 150 Ah batteries would exceed eight hours. For heavier loads, you can add parallel strings.

Lento Battery Options:

  • Tubular Lead‑Acid: 150–260 Ah
  • AGM/VRLA: 42–200 Ah
  • Lithium‑Ion: 100–300 Ah at 51.2 VDC

 

Step 4: Install and Configure Your System

  1. Mount the UPS and Batteries
    • In a well‑ventilated, cool area (20 – 25 °C)
    • Away from direct sunlight or heat sources
  2. Connect Batteries
    • Series‑connect for voltage
    • Parallel strings for higher Ah as needed
    • Use properly rated cables and fuses
  3. UPS Configuration
    • Set the inverter mode for extended backup (some models allow ECO or inverter priority modes)
    • Disable unnecessary features that draw extra standby power
  4. Load Management
    • Connect only essential devices to UPS outlets
    • Use separate circuits for heavy loads (e.g., refrigerators)

 

Step 5: Maintenance and Best Practices

  • Regularly Test the System
    Perform a full discharge test every 6 – 12 months to ensure batteries meet runtime expectations.
  • Keep Batteries Charged
    Maintain float charging when not in use and avoid deep discharges beyond recommended DoD.
  • Monitor Temperatures
    Excess heat shortens battery life. Ensure adequate airflow around UPS and battery bank.
  • Replace Batteries on Schedule
    • Lead‑acid: every 3 – 5 years
    • Lithium‑ion: every 8 – 12 years
  • Firmware and Firmware Updates
    If your UPS support firmware upgrades or software monitoring, keep them up to date for best performance.

 

Why Choose Lento for Extended UPS Backup?

Lento’s DSP‑based Online UPS systems are engineered for reliability and long runtimes:

  • Pure Sine-Wave Output preserves sensitive electronics
  • Zero Transfer Time keeps devices running seamlessly
  • Wide Input Voltage Range tolerates unstable grids
  • Generator Compatibility for extended outages
  • Remote Monitoring via Web, SNMP, or GSM
  • Robust Protections: short circuit, overload, battery over/under voltage

Lento models paired with tubular or lithium batteries give you a cost‑effective, high‑performance backup solution that can comfortably run for eight hours or more.

 

Conclusion

Using a UPS as an inverter for eight hours is entirely feasible when you select the right UPS capacity, properly size your battery bank, and manage the load effectively. High‑quality Online UPS systems—such as those from Lento—combined with deep‑cycle batteries offer clean, uninterrupted power, zero transfer time, and reliable performance throughout long outages.

By following these steps and best practices, you can ensure your home or office stays powered, productive, and protected, even during extended blackouts.

 

Call to Action

Ready to build a long‑duration power backup system for your home or business? Explore Lento’s Online UPS solutions and compatible battery ranges. Our team can help you configure the perfect setup for eight‑hour backups and beyond. Contact Lento today to discuss your requirements and secure uninterrupted power for every scenario.

 

Frequently Asked Questions (FAQs)

1. Can any UPS run for eight hours on battery?
Only if it has a sufficiently large battery bank. A small 600 VA UPS with standard batteries will last only minutes.

2. What is the ideal depth of discharge for lead‑acid batteries?
Staying at or below 50% DoD preserves battery life and cycle count.

3. Are lithium‑ion batteries better for long runtime?
Yes. Lithium‑ion offers higher cycle life, deeper discharge capability, and faster recharge—though at a higher upfront cost.

4. How often should I test my UPS backup runtime?
Conduct a full discharge test at least once a year, more often if outages are frequent.

5. Will my UPS and battery require special maintenance?
Lead‑acid batteries need water top‑ups; AGM and lithium are maintenance-free. The UPS itself should be kept cool and clean, with firmware updated if supported.