To calculate the backup time, use the following formula: Backup Time (in hours) =Battery Capacity (in Ah) * Battery Voltage (in V) * Battery Efficiency (in %) / Connected Load (in W/h)
For example, 1. If you have a 1500VA UPS with a 12V 100Ah battery, and the total wattage of your load is 800W, the backup time can be calculated as follows:
Backup time = (battery capacity ÷ power requirement of load) × 0.7 Backup time = (12V × 100Ah ÷ 800W) × 0.7 Backup time = 1.05 hours or 63 minutes Note: The factor of 0.7 is used to account for battery efficiency and other losses.
How to calculate Inverter Battery Backup Time 2024
How to Calculate UPS/Inverter Battery Backup Time?
In today's world, where power outages are becoming more frequent and unpredictable, having an Uninterruptible Power Supply (UPS) or Inverter at home or office is essential. But how do you calculate the battery backup time of your UPS or Inverter? This question has been a hot topic lately, with many people searching for answers online. In this blog, we will guide you through the steps to calculate your UPS/Inverter battery backup time, using popular methods and techniques. So, let's get started and learn how to ensure uninterrupted power supply during emergencies!
There are different methods to calculate the battery backup time of your UPS/Inverter. Here are two popular methods:
Method 1: Using Battery Capacity and Load
The first method to calculate UPS/Inverter battery backup time is by using the battery capacity and the load. The battery capacity is the amount of energy that the battery can store, while the load is the amount of energy that your appliances or devices consume.
Step 1:Determine the Battery Capacity in Ah
To determine the battery capacity in Ah, check the battery label or manual. For example, if the battery is labeled as 12V 100Ah, the battery capacity is 100Ah.
Step 2:Determine the Load Wattage in W
To determine the load wattage in W, add up the wattage of all the devices connected to the UPS/Inverter. For example, if you have a computer with a power consumption of 150W and a monitor with a power consumption of 50W, the load wattage is 200W.
Step 3: Calculate the Backup Time
To calculate the backup time, use the following formula:
Backup Time (in hours) =Battery Capacity (in Ah) * Battery Voltage (in V) * Battery Efficiency (in %) / Connected Load (in W/h)
For example,
1. If you have a 1500VA UPS with a 12V 100Ah battery, and the total wattage of your load is 800W, the backup time can be calculated as follows:
Backup time = (battery capacity ÷ power requirement of load) × 0.7
Backup time = (12V × 100Ah ÷ 800W) × 0.7
Backup time = 1.05 hours or 63 minutes
Note: The factor of 0.7 is used to account for battery efficiency and other losses.
2. Suppose you have an inverter battery with a capacity of 150 Ah and an input voltage of 12 V, and you want to power three tube lights, three fans, and a Wi-Fi router using this battery. In this scenario, you may be wondering how long your appliances will run on this battery and what will be the battery backup time. To find out, let's calculate the backup time of your inverter battery and determine how long your devices will be powered.
Taking your inputs into consideration, you can calculate your total load, like:
So, the total load in your case is 120 + 225 + 20 = 365 Watts.
Now, let us apply all these values in the above-said battery backup time formula.
Backup Time (in hours) = 150 x 12 / 365 = 4.9
So, your inverter battery will last around 4.9 hours to keep your needed appliances running.
Method 2: Using Battery Discharge Rate
The second method to calculate UPS/Inverter battery backup time is by using the battery discharge rate. The battery discharge rate is the rate at which the battery discharges during a power outage.
To calculate the backup time using this method, follow these steps:
Step 1:Determine the discharge rate of your battery. This information can usually be found on the battery or in the product manual.
Step 2:Determine the capacity of your battery. This is the same as step 1 in method 1.
Step 3: Calculate the backup time by dividing the capacity of the battery by the discharge rate.
For example, if the discharge rate of your battery is 10A, and the capacity of your battery is 100Ah, the backup time can be calculated as follows:
Backup time = battery capacity ÷ discharge rate
Backup time = 100Ah ÷ 10A
Backup time = 10 hours
Calculating UPS/Inverter battery backup time is essential to ensure uninterrupted power supply during emergencies. The two methods discussed in this blog, using battery capacity and load wattage, and using runtime provided by the manufacturer, can help you determine the backup time of your UPS/Inverter accurately. It's important to keep in mind that backup time can vary depending on several factors, such as battery age, temperature, and load type. Therefore, it's recommended to test your UPS/Inverter regularly to ensure optimal performance during power outages.
How to Improve Your Inverter Battery’s Backup Time?
If you want to improve your inverter battery's backup time, there are several steps you can take to optimize its performance. Here are a few things you can do:
By following these tips, you can significantly improve the backup time of your inverter battery and ensure uninterrupted power supply during emergencies.
FAQ-
How long does it take to charge A 200 Ah battery?
100 % charge of 200 Ah with 2 A current will take 100 hours or about 4 days. With 12 A 16.67 hours will be needed. The battery should be full charged before the next power outage. You want to be prepared for the next outage soon.
How long to charge A 200Ah battery calculator?
While this battery charge time calculator formula is simple, it is the least accurate. Example: Suppose the battery capacity is 200Ah, and the charging current is 20 amps. In this case, the battery charge time will be: Charge Time = 200Ah ÷ 20A = 10H.
How do you calculate charging time?
So charging current for 120Ah Battery = 120 x (10/100) = 12 Amperes but due to losses, we can take 12-14Amperes for charging purpose. Suppose we took 13 Amp for charging purpose, then charging time for 120Ah battery = 120 / 13 = 9.23 Hrs.
What is the life of battery 200 Ah?
The total load for the same is = 350 Watts. Therefore, 200*12/350 = 6.8 hours (Approx.) Finally, 6.8 hours is your inverter's battery backup. In simple words, your battery will last 6.8 hours while running these appliances.
What size charger for 200Ah battery?
between 20A and 40A
To determine the appropriate charger size for a 200Ah lithium battery, it is recommended to follow the general rule of thumb, which suggests a charging current of 10-20% of the battery's capacity. Applying this rule to a 200Ah battery, the charger size should be between 20A and 40A
How long will a 200Ah battery last?
To calculate the runtime of a 200Ah lithium battery, you need to know the wattage of the device or appliance and the battery voltage. Therefore, A 12V 200Ah lithium battery will last for 2.4 hours when powering a 1000W appliance continuously.
What is the formula for battery time?
The calculator applies the formula: Capacity (Ah) x Voltage (V) x Efficiency / Load Power (W). This equation gives an estimated runtime based on the input values. For instance, a 100 Ah battery at 12V with 90% efficiency powering a 50W load would have a runtime of (100 Ah x 12V x 0.9) / 50W = 21.6 hours.
How do you calculate charge in time?
It is measured in coulombs (C) and can be calculated using the formula, Charge (C) = Current (A) x Time (s).